Guide
Do You Need a Permit for a Range Hood or Bathroom Exhaust Fan?
Adding a fan or a ducted hood is mechanical permit work in the offices we read; swapping one in place is exempt in some, including statewide in New Jersey for hoods up to 400 cfm. Where the duct may end, the 50 cfm bathroom minimum, and when a big hood brings a make-up air requirement.
A new bathroom fan or a ducted range hood that did not exist before is mechanical work, and the offices we read treat it as permit work; the wiring for it is electrical work, and Little Rock, in our dataset, prices a bath fan on its electrical fee schedule. Replacing a fan or hood in the same spot is where the answers split. New Jersey’s statewide code lets you swap either without a permit when the new unit vents on its own to the outdoors (and a hood stays at or under 400 cubic feet per minute or the old hood’s rate), Virginia’s exempts replacing an appliance not fueled by gas or oil, and Indianapolis exempts like-for-like replacements too. Other offices name replacements as permit work.
- New fan or ducted hood
- Permitmechanical; wiring is electrical work
- Swap in place, New Jersey
- No permitN.J.A.C. 5:23-2.7, hood at or under 400 cfm
- Bathroom fan minimum
- 50 cfm intermittent, 20 cfm continuousR303.3 as Wichita prints it
- Make-up air
- Above 400 cfmNorth Carolina rule, 2018 reading
- Offices that name fans or hoods
- 38from our dataset
- Portland, OR fee for one fan
- $187.04$167 minimum plus 12% state surcharge
Two facts decide this: the hood or fan’s airflow rating in cubic feet per minute (cfm), and where its duct will end. With both in hand, ask your office: “I am [replacing a range hood with a [cfm] cfm model / adding a bathroom fan] at [address]. The duct will end at [the wall / the roof / the old duct]. Do I need a mechanical permit, an electrical permit, or neither? Does my house need make-up air for this hood?”
Swapping one out
New Jersey, statewide. Ordinary maintenance “may be made without filing a permit application with or giving notice to the construction official,” and the state’s list of it includes “Replacement of kitchen range hoods in dwelling units, provided that the replacement hood exhaust rate does not exceed the exhaust rate of the existing hood or the exhaust rate of the replacement hood does not exceed 400 cubic feet per minute (cfm), and provided that the hood recirculates or vents independently to the outdoors.” A bathroom fan replacement is on the same list with the same outdoor-venting condition; our bathroom remodel guide quotes it. A hood that ties into another duct, or a bigger hood than the one it replaces above 400 cfm, falls outside the rule.
Virginia, statewide. The building code exempts “Replacement of mechanical appliances provided such equipment is not fueled by gas or oil” in houses. Arlington County, in its rule as verified in our dataset, applies that to exhaust systems: replacements “of the same type, size and location do not require a permit, unless its equipment is fueled by gas.” Henrico County’s permit page, read today, requires a permit for “the initial installation” of fixtures including “Fans, attic/ceiling/exhaust,” while it lists other equipment under “new and replacement installations,” so a fan swap there falls outside the permit list.
Indianapolis. Its mechanical code (Sec. 536-201(b)), as recorded in our dataset, exempts replacing an attic fan, a bathroom exhaust fan, a range hood exhaust fan or a whole house fan.
The other side. Several offices in our dataset name the replacement itself as permit work: Miami lists a bathroom exhaust fan replacement as a mechanical Easy Permit, open only to qualified contractors; Pittsburgh’s minor alteration permit scope covers exhaust fan replacement or installation; and Fort Worth, Omaha, Madison and Ann Arbor write replacing, changing or repairing exhaust equipment into the work that needs a permit; and Prince George’s County, Maryland, marks replacing a kitchen stove exhaust as electrical permit work. Outside New Jersey, Virginia and Indianapolis, ask before you treat a swap as exempt.
Where the duct may end
Wichita and Sedgwick County’s amended code spells out where a bathroom fan’s duct may end, and shows one local exception to the rule. Its version of M1505.2 says bathroom exhaust “shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors,” then allows discharge into an attic only when the duct ends “a minimum of thirty-six (36) inches above the top of the ceiling framing members,” the attic is properly ventilated and not an unvented attic assembly, the duct ends above the insulation with a “goose-neck,” and any duct over 5 feet run above the insulation is insulated. That exception is Wichita’s amendment; we could not read the model code itself today, so do not assume your office allows any attic discharge.
New Jersey’s hood rule accepts a hood that “recirculates,” meaning a ductless hood that filters air back into the kitchen. A ductless hood has no duct to inspect.
How big a bathroom fan
Wichita’s code, at R303.3, lets a bathroom skip the openable window when it has light and a fan, and sets the fan at “50 cubic feet per minute (24 L/s) for intermittent ventilation or 20 cubic feet per minute (10 L/s) for continuous ventilation.” In a bathroom without that window, a switched fan rated under 50 cfm does not meet the line.
Big hoods and make-up air
A strong hood takes air out of a house faster than gaps let it back in. The concern behind the rule, which North Carolina’s exception for sealed and powered appliances reflects, is a house drawn down far enough to pull exhaust from a naturally vented furnace or water heater back indoors. The answer is make-up air: a damper or duct that lets in air to replace what the hood removes. North Carolina’s rule, as its fire marshal quoted it in a 2018 interpretation, reads: “Exhaust hood systems capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) shall be provided with makeup air at a rate approximately equal to the exhaust air rate that is in excess of 400 cubic feet per minute,” and the make-up air must have a means of closure and start automatically with the hood. North Carolina added an exception: where every appliance in the house is “direct-vent, power-vent, unvented, or electric,” the line moves to 600 cfm. The quoted rule is from the 2012 North Carolina Mechanical Code; we did not confirm that the current North Carolina mechanical and residential codes keep the same wording, and other states adopt their own; the point to take to your office is the 400 cfm number. A 600 cfm hood over a gas range in a house with a gas water heater is the case to ask about before you buy.
New Jersey’s replacement rule uses the same 400 cfm number: a swap to a stronger hood above 400 cfm needs a permit there.
Clearance above the cooktop
Wichita’s code also adds a rule about the space above a range: “not less than thirty (30) inches (760 mm) to combustible material or metal cabinets,” reduced to 24 inches where a metal hood or protected cabinet bottom is installed or the over-range appliance is listed for it. A microwave hood combination follows its own listing and instructions.
What the dataset shows
We read every confirmed rule in our dataset that mentions exhaust fans, bathroom fans, kitchen or range hoods, or exhaust systems. Thirty-eight offices name them as permit work or price them on a fee schedule; five of those (Indianapolis; Newark and Jersey City under the New Jersey rule; Arlington County and Henrico County under Virginia’s) let a like-for-like replacement go without one, on the conditions above. San Antonio’s home remodeling handout, read today, says “To install HVAC equipment, exhaust fans, kitchen hoods, and dryer ducts a permit is required.”
Three fee lines read today show how small the item is and how the minimum decides the bill:
| Office | Fee line | What one hood or fan costs |
|---|---|---|
| Portland, Oregon (July 10, 2026) | Residential kitchen hood or single-duct bath fan, $24.00 each; one and two family minimum $167.00; Oregon’s 12% surcharge on every mechanical permit | $187.04 for a single item |
| Manatee County, Florida (schedule effective 04/01/2023) | Mechanical Standard, $62, which lists “Rangehood” | $62 |
| San Antonio, Texas (FY 2027 schedule, revised October 2026) | Mechanical permit base fee $57.50, plus $7.19 per “ventilating fan” or “hood served by mechanical exhaust” | $64.69 |
Method
Read on November 18, 2026: New Jersey’s N.J.A.C. 5:23-2.7, Virginia’s 13VAC5-63-80, Henrico County’s permit page, the Wichita-Sedgwick County code, the North Carolina fire marshal’s interpretation, and the Portland, Manatee County and San Antonio documents (San Antonio’s handout for the permit rule, its FY 2027 schedule for the fee). The dataset count covers rules marked confirmed; Anchorage (fan rules in an FAQ) and Henderson (commercial hood designs only) were left out. Arlington County, Indianapolis, Miami, Pittsburgh, Fort Worth, Omaha, Madison and Ann Arbor and Prince George’s County are cited from their verified rows, and each office’s page here shows its read date. ICC’s own code site refused automated readers today, so the model code’s wording is not quoted; the bathroom rates and attic text are Wichita’s amended version.
Do You Need a Permit for a Range Hood or Bathroom Exhaust Fan?: figures as of 28 Sep 2026, 137 jurisdictions. Now 178.
Sources
- New Jersey Uniform Construction Code, N.J.A.C. 5:23-2.7 Ordinary maintenance: replacing a kitchen range hood (400 cfm or the old hood's rate) and a bathroom exhaust fan that vents independently outdoors, without a permit. (accessed )
- Virginia Uniform Statewide Building Code, 13VAC5-63-80, Section 108.2 item 14.4: replacing mechanical appliances not fueled by gas or oil in houses without a permit. (accessed )
- Wichita-Sedgwick County Unified Building and Trade Code: amended R303.3 (bathroom ventilation rates), M1501.1 and M1505.2 (outdoor discharge and the ventilated-attic exception), M1503.1.5 (clearance above a cooking top). (accessed )
- North Carolina Office of State Fire Marshal, Kitchen Exhaust Makeup Air Exceptions (2018 interpretation of the 2012 North Carolina Mechanical Code 505.2): make-up air above 400 cfm, and above 600 cfm where every appliance is direct-vent, power-vent, unvented or electric. (accessed )
- City of Portland, Oregon, Mechanical Permit Fee Schedule effective July 10, 2026: $24 per residential kitchen hood or single-duct bath fan; $167 minimum fee for one and two family dwellings. (accessed )
- City of Portland, Oregon, current fee schedules page: the 12% State of Oregon surcharge on building, plumbing, electrical and mechanical permits. (accessed )
- Henrico County, Virginia, When a Permit is Required: exhaust fans among fixtures permitted at initial installation, apart from new and replacement installations. (accessed )
- Manatee County, Florida, Building Fee Schedule (effective 04/01/2023): Mechanical Standard, $62, including a rangehood. (accessed )
- City of San Antonio Development Services, home remodeling handout: a permit to install exhaust fans and kitchen hoods. (accessed )
- City of San Antonio FY 2027 Development Fee Schedule (revised October 2026): mechanical permit base fee $57.50 and $7.19 per ventilating fan or hood served by mechanical exhaust. (accessed )
Get rule-change alerts
We catch permit rule and fee changes in our verification passes and post them to the rule tracker. Get them by email instead.