PermitNotebook / Guides

Guide

Do You Need a Permit to Add an Egress Window?

Yes: cutting or enlarging an opening for an escape window is building permit work in every rule we read, inspected when the wall is cut. The arithmetic of 5.7 square feet, the window well and ladder rules (and how Wichita tightened them), what the application asks for, flat fees of $99 and $101, and the smoke alarm check at final.

Yes. Cutting a new opening in a basement wall for an escape window, or enlarging an existing window to escape size, is building permit work in every handout we read, and the first inspection comes when the wall is open: Ankeny, Iowa, inspects “at the time the opening is cut in the exterior wall.” The permit covers more than the window. The inspector checks the header over the opening, the window’s clear opening, the well outside, its ladder and drainage, and in some cities the smoke and carbon monoxide alarms in the whole house before signing off.

New or enlarged opening
Building permitin every rule we read
Clear opening
5.7 sq ft (820.8 sq in)5.0 sq ft for a grade floor opening
Minimums
20 in. wide, 24 in. high, sill at 44 in. or less
Window well
9 sq ft, 36 in. out from the wallladder if deeper than 44 in.
Flat fees read today
$99 Aurora, CO; $101 Hastings, MN

Get the window’s net clear opening from the manufacturer’s chart first (not its rough opening or glass size), then send your office: “I plan to cut a new egress window into the [basement / bedroom] wall at [address]. The wall is [poured concrete / block / wood frame], the window is a [casement / slider] with a clear opening of [width] by [height] inches, and the well will be [depth] inches deep. What do you need on the plan for the header, and will you check the smoke alarms at final?”

The numbers, and why the two minimums are not enough

The escape opening has to meet four tests at once. Ankeny’s handout: a “minimum net clear openable area of 5.7 square feet,” a net clear width of 20 inches and height of 24 inches, and a sill “not more than 44 inches above the floor.” Its handout adds a warning: “using both the minimum width and height dimensions will not provide the minimum required area.” It is easy to check. 20 by 24 inches is 480 square inches, and 5.7 square feet is 820.8, so a window that just meets both minimums is about 340 square inches short.

At 20 inches wide, the clear height has to be about 41 inches (820.8 divided by 20 is 41.04); at 24 inches high, the width has to be about 34.2 inches. Ankeny prints a table of those pairs, from 20 by 41 up through wider and shorter openings, and its numbers match that arithmetic.

A window whose sill sits no more than 44 inches above or below the finished ground outside is a “grade floor” opening in the Hastings, Inver Grove Heights and Ankeny handouts, and the area drops to 5.0 square feet (720 square inches). That covers a basement window in a well no deeper than 44 inches, the depth at which a ladder becomes required. At 720 square inches, a 20 inch wide opening needs 36 inches of clear height, and a 24 inch high one needs 30 inches of width. Maplewood’s handout defines the clear opening: “It is not the rough opening size or the glass panel size, but the actual opening a person can crawl through.” On a slider that is only the part that slides open, so compare manufacturers’ clear-opening figures, never frame sizes.

Wichita is different. Wichita and Sedgwick County amended these sections: their code requires “a minimum net clear opening of 4.5 (0.418 m2) square feet with the window in an open position, with a total break-out area of 5.7 (0.530 m2) square feet,” a minimum clear height of 19 3/4 inches for single, double hung and awning windows, and a minimum clear width of 17 inches for casements and sliders and 30 1/4 inches for single and double hung windows. A window chosen for Wichita’s rule may not pass in a Minnesota city, and the reverse. Read your own office’s version before you order.

For more on the basement itself, including why one bedroom’s opening can serve the whole basement, see our guide to finishing a basement.

The well, the ladder and the cover

A below-grade window needs a well that lets it open fully. Ankeny requires “a minimum net clear area of 9 square feet with a minimum horizontal projection of 36 inches.” A well deeper than 44 inches needs a permanently affixed ladder or steps, which may intrude up to 6 inches into the well. The rung spacing is where offices differ:

RuleRung widthProjection from wallRung spacingOther
Ankeny, Iowa12 in. minimum3 in. minimum18 in. on center or less; bottom rung no more than 18 in. upnone stated
Wichita-Sedgwick County12 in. inside width3 in. to the back of the rung12 in. on center or lessa guard or a 20 psf cover on any well deeper than 30 in., with an escape hatch that opens with 30 pounds of force or less

Wichita also added a drainage rule: wells “shall be designed for proper drainage by connecting to the existing foundation drainage system” or another approved method, and where no foundation drain exists, “the entire window well area shall have a minimum depth of 12” of washed gravel or crushed rock below the floor level,” unless the foundation sits on well-drained sand or gravel soils (the code’s Group I soils). Maplewood’s older handout says simply that “Window wells must have a drain connected to the house foundation drainage system.”

Under a deck. Maplewood: “If an egress window is located under a deck or porch, the code requires at least 36 inches between the top of the window well and the bottom of the deck or porch joists.” Hastings prints the same rule, and Ankeny allows a window under a deck if it can fully open with “a path not less than 36 inches in height to the yard.”

What the application asks for

Hastings lists a site plan “showing location on property and distance to property lines,” a construction plan “showing dimensions of window well & proposed framing of window,” the window dimensions and type, and an owner-contractor waiver if you do the work yourself. Inver Grove Heights wants an elevation drawing and a “Section showing header size and distance of windowsill to floor and depth of window well if applicable.” Neither handout says who must design a header cut into a concrete or block foundation; ask your office whether it wants an engineer’s detail before you hire a saw cutter.

In Arlington County, Virginia, as verified in our dataset, the county counts “adding a window well for egress” as an addition, so ask how that changes the review there.

Inspections and the alarm check

The inspections we read run in the same order: Hastings lists “Window Rough-In/Framing,” then flashing photos, then a final at which “Interior access is required to inspect new windows and smoke & CO alarms throughout the home.” Its packet adds that “All alarms must be installed and operational throughout the entire home at final inspection,” hardwired and interconnected unless existing construction does not allow it. Inver Grove Heights requires smoke alarms in bedrooms, the halls outside them and every level, and carbon monoxide alarms within 10 feet of bedrooms. If your house has old battery alarms on one floor, budget for alarms as part of the window job.

Two flat fees and a valuation fee

Two offices price the job flat. Aurora, Colorado’s 2026 schedule lists “Egress Window Installation” at $99 each, with city use tax on materials collected separately; Hastings charges a “New Egress Window Permit Fee” of $101.00. Inver Grove Heights bases the fee on job valuation, so a contractor’s price for the cut, window and well sets it.

Replacing an egress window you already have

A replacement in the same opening is a different question, with its own exception for older windows that are smaller than today’s rule. Our guide to window replacement permits covers it.

Method

We read four city handouts (Ankeny, Hastings, Inver Grove Heights, Maplewood), the Wichita-Sedgwick County code and Aurora’s 2026 flat fee schedule on November 18, 2026. The three Minnesota handouts follow the Minnesota Residential Code, and Maplewood’s is dated 2015; Wichita’s sizes are its local amendment. Arlington County is cited from its verified row, with its read date on its page here. The square inch figures are our arithmetic. ICC’s own code site refused automated readers today, so the model code is not quoted directly.

Do You Need a Permit to Add an Egress Window?: figures as of 28 Sep 2026, 137 jurisdictions. Now 178.

Sources

Get rule-change alerts

We catch permit rule and fee changes in our verification passes and post them to the rule tracker. Get them by email instead.

We may send occasional verified rule-change notes for your area; unsubscribe anytime. See our privacy policy.